SHEFFIELD BRONZE PAINT CORP -- PIGMENT - BURNT UMBER -- 8010-00-247-4341
=====================  Product Identification  =====================

Product ID:PIGMENT - BURNT UMBER
MSDS Date:05/01/1989
FSC:8010
NIIN:00-247-4341
=== Responsible Party ===
Company Name:SHEFFIELD BRONZE PAINT CORP
Address:17814 S WATERLOO RD
City:CLEVELAND
State:OH
ZIP:44119-3221
Country:US
Info Phone Num:216-481-8330
Emergency Phone Num:216-481-8330
CAGE:91071
=== Contractor Identification ===
Company Name:SHEFFIELD BRONZE PAINT CORP
Address:17814 S WATERLOO RD
Box:City:CLEVELAND
State:OH
ZIP:44119-3221
Country:US
CAGE:91071
Company Name:STEVEN INDUSTRIES
Address:39 AVENUE C
Box:8
City:BAYONNE
State:NJ
ZIP:07002-3417
Country:US
Phone:201-437-6501
CAGE:33150

=============  Composition/Information on Ingredients  =============

Ingred Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Health Hazards Acute and Chronic:EYES: SEVERE IRRITATION, REDNESS,
    TEARING, BLURRED VISION. SKIN: PROLONGED OR REPEATED CONTACT:
    MODERATE IRRITATION, DEFATTING, DERMATITIS. BREATHING: NASAL &
    RESPIRATORY IRRITATION, DIZZINESS, FATIGU E, HEADACHE,
    UNCONSCIOUSNESS, & EVEN ASPHYXIATION. SWALLOWING: GASTROINTESTINAL
    IRRITATION, NAUSEA, VOMITING, DIARRHEA.*
Effects of Overexposure:* ASPIRATION OF MATERIAL INTO THE LUNGS CAN
    CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.

=======================  First Aid Measures  =======================

First Aid:SKIN: WASH EXPOSED AREA WITH SOAP & WATER. REMOVE
    CONTAMINATED CLOTHING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
    EYES: FLUSH WITH LARGE AMOUNTS OF WATER, LIFTING UPPER & LOWER LIDS
    OCCASIONALLY. G ET MED AID. IF BREATHED: IF AFFECTED REMOVE
    INDIVIDUAL TO FRESH AIR. IF BREATHING DIFFICULT, ADMINISTER OXYGEN.
    IF BREATHING HAS STOPPED GIVE ARTIFICIAL RESPIRATION. KEEP WARM,
    QUIET. GET MED AID.

=====================  Fire Fighting Measures  =====================

Flash Point:106F,41C
Lower Limits:1
Extinguishing Media:CO2, FOAM, DRY CHEMICAL, FOG, DO NOT USE DIRECT
    WATER STREAM.
Fire Fighting Procedures:DO NOT ENTER FIRE AREA WITHOUT PROPER
    PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR. THEY MAY
    TRAVEL ALONG GROUND OR ACCUMULATE IN LOW UNVENTILATED AREAS.
    PRODUCT WILL FLOAT AND CAN BE IGNITED ON SURFACE OF WATER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE IGNITION SOURCES (FLARES, FLAMES,
    PILOT LIGHTS, ELEC SPARKS). EXCLUDE PERSONS NOT WEARING PROTECTIVE
    EQUIP FROM AREA TILL CLEANUP COMPLETED. STOP SPILL AT SOURCE. DIKE
    AREA. PUMP LIQUID TO S ALVAGE TANK. REMAINING LIQUID MAY BE TAKEN
    UP **
Neutralizing Agent:N/K	** W/ABSORB. SHOVEL INTO CNTNR. PREVENT RUNOFF
    TO SEWER,STREAM,WATERBODIES.

======================	Handling and Storage  ======================

Handling and Storage Precautions:EMPTIED CONTAINERS RETAIN HAZARDOUS
    PRODUCT RESIDUE. ALL PRECAUTIONARY STATEMENTS MUST BE FOLLOWED WHEN
    EMPTY.
Other Precautions:DO NOT USE OR STORE EMPTY DRUM NEAR OPEN FLAME,
    SPARKS OR WELDING TORCHES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLV IS EXCEEDED, NIOSH/MSHA APPROVED
    SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPIECE OPERATED IN
    PRESSURE DEMAND/OTHER POSITIVE PRESSURE MODE ADVISED. OSHA REGS
    ALSO PERMIT OTHER NIOSH/MSHA  RSPRTR UNDER SPECIFIED CONDITIONS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) LOCAL EXHAUST
    VENTILATION TO MAINTAIN BELOW TLV'S.
Protective Gloves:WEAR RESISTANT GLOVES (BUNA-N, NITRILE)
Eye Protection:CHEMICAL SPLASH GOGGLES, SAFETY GLASSES
Other Protective Equipment:TO PREVENT REPEATED OR PROLONGED SKIN
    CONTACT, WEAR IMPERVIOUS CLOTHING AND BOOTS.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:325 TO 385F
Vapor Density:> AIR
Spec Gravity:12.8 LBS/GAL
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:19.2

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS (NITRIC ACID, PERMANGANATES)
    ETC.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
    VARIOUS HYDROCARBONS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DESTROY BY LIQUID INCINERATION. MATERIAL
    COLLECTED ON ABSORBENT MATERIAL MAY BE DEPOSITED IN A POSTED TOXIC
    SUBSTANCE LANDFILL IN ACCORDANCE WITH LOCAL STATE AND FEDERAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.